Figure 1
Example of test set-up for log-periodic antenna
         Top view                                                                                                 Dimensions in millimetres

Legend:        
1    ESA (grounded locally if required in test plan)    16    power line filter
2    ground plane    17    fibre optic feed through
3    low relative permittivity support (er ≤ 1.4); thickness 50 mm    18    bulk head connector
4    ground straps    19    stimulating and monitoring system
5    LV harness    20    RF signal generator and amplifier
6    HV lines (HV+, HV-)    21    high quality coaxial cable e.g. double shielded (50 Ω)
7    LV load simulator    22    optical fibre
8    impedance matching network (optional)    23    log-periodic antenna
9    LV AN    24    RF absorber material
10    HV AN    25    AC power mains
11    LV supply lines    26    AMN for AC power mains
12    HV supply lines    27    AC charging load simulator
13    LV power supply 12 V / 24 V / 48 V (placed on the bench)    28    50 Ω load
14    additional shielded box (optional)    29    AC lines
15    HV power supply (should be shielded if placed inside ALSE)        

a0c0