5.1.1.3.

[DEL]

a2c0
5.1.1.3.

Connectors
Connectors (including vehicle inlet) are deemed to meet this requirement if:
(a)    They comply with 5.1.1.1. and 5.1.1.2. when separated without the use of tools, or
(b)    They are located underneath the floor and are provided with a locking mechanism, or
(c)    They are provided with a locking mechanism and other components shall be removed with the use of tools in order to separate the connector, or
(d)    The voltage of the live parts becomes equal or below DC 60V or equal or below AC 30V (rms) within one second after the connector is separated.

a0c0