3.1.

The artificial network(s) to be used for the measurement on vehicle are 
(a)    The AMN(s) defined in Appendix 8 clause 4 for AC power lines;
(b)    The DC-charging-AN(s) defined in Appendix 8 clause 3 for DC power lines.
Artificial networks
The AMN(s)/DC-charging-AN(s) shall be mounted directly on the ground plane. The cases of the AMN(s)/DC-charging-AN(s) shall be bonded to the ground plane.
The conducted emissions on AC and DC power lines are measured successively on each power line by connecting the measuring receiver on the measuring port of the related AMN/DC-charging-AN. The measuring port of the AMN/DC-charging-AN inserted in the other power lines shall be terminated with a 50 Ω load.
The AMN(s)/DC-charging-AN(s) shall be placed in front, aligned and on the same side of the vehicle power charging plug.
16-1-4 may be used.

a0c0