5.2.5.9. Procedure of charging failure

The charging failure is carried out with a suitable charger and consists of the following steps:
(a)     Charging at constant power during t'1,
(b)     Charging at maximum current as recommended by the manufacturer during 30 minutes. During this phase, the charger shall supply maximum current as recommended by the manufacturer.
a0c0