3.1.

General test conditions and requirements

The following condition shall apply to the test:
(a)     The test shall be conducted at an ambient temperature of 20 ± 10 °C,
(b)     At the beginning of the test, the SOC shall be adjusted to a value in the upper 50 per cent of the normal operating SOC range;
(c)     At the beginning of the test, all protection devices which effect the function of the tested-device and which are relevant to the outcome of the test, shall be operational.

a0c0