3.1.

General test conditions

The following condition and requirements shall apply to the test:
(a) The test shall be conducted at an ambient temperature of 20 ± 10 °C;
(b) At the beginning of the test, the SOC shall be adjusted to a value in the upper 50 per cent of the normal operating SOC range;
(c) At the beginning of the test, all internal and external protection devices which would affect the function of the tested-device and which are relevant to the outcome of the test shall be operational.