3.3. Standard charge and observation period

Directly after termination of the discharging the tested-device shall be charged with a standard charge as specified in Annex 8, Appendix 1 if not inhibited by the tested-device. The test shall end with an observation period of 1 h at the ambient temperature conditions of the test environment.