3. First repeated sampling
A sample of four retro-reflectors is selected at random from stock manufactured after alignment.
The first sample of two is marked C, the second sample of two is marked D.
a3c0
3. Repeated sampling
In the cases of A3, B2, B3 a repeated sampling, third sample C of two retro-reflectors and fourth sample D of two retro-reflectors, selected from stock manufactured after alignment, is necessary within two months' time after the notification.
a0c0