3.2.

[DEL] Inflate the tyre to an inflation pressure of 2.5 bar and condition the tyre-and-wheel assembly at a test room temperature of 38 ºC ± 3 ºC for not less than three hours.

a10c0
3.2.

Carry out the procedure as detailed in paragraphs 1.2. to 1.5. above with a test room temperature at 38 ºC ± 3 ºC in relation to conditioning the tyre-and-wheel assembly as detailed in paragraph 1.4. The temperature sensor shall be at a distance not less than 0.15 m and not more than 1.00 m from the tyre sidewall.

a8c0
3.2.

Carry out the procedure as detailed in paragraphs 1.2. to 1.5. above with a test room temperature at 38 C + 3 °C in relation to conditioning the tyre-and-wheel assembly as detailed in paragraph 1.4. The temperature sensor shall be at a distance not less than 0.15 m and not more than 1.00 m from the tyre sidewall.

a7c0
3.2.

Carry out the procedure as detailed in paragraphs 1.2. to 1.5. above with a test room temperature at 38 °C ± 3 °C in relation to conditioning the tyre-and-wheel assembly as detailed in paragraph 1.4.

a0c0