High Voltage Artificial networks (HV-AN)
For an ESA powered by HV, a 5 µH / 50 Ω HV-AN as defined in Figure 3 shall be used.
The HV-AN(s) shall be mounted directly on the ground plane. The grounding connection of the HV-AN(s) shall be bonded to the ground plane.
Measurement ports of HV-AN(s) shall be terminated with a 50 Ω load.
The HV-AN impedance ZPB (tolerance ± 20 %) in the measurement frequency range of 0,1 MHz to 100 MHz is shown in Figure 2. It is measured between the “Vehicle/ESA HV” and “GND” terminals (of Figure 3) with a 50 Ω load on the measurement port and with the “HV supply” and “GND” terminals short circuited