3.

Direct Current charging Artificial Networks (DC-charging-AN)

For a vehicle in charging mode connected to a DC power supply, a 5 µH / 50 Ω DC-charging-AN as defined in Figure 6 shall be used.
Measurement ports of DC-charging-AN(s) shall be terminated with 50 Ω loads.
The DC-charging-AN impedance ZPB (tolerance ± 20 %) in the measurement frequency range of 0,1 MHz to 100 MHz is shown in Figure 7. It is measured between the terminals “Vehicle/ESA HV” and “GND” (of Figure 6) with a 50 Ω load on the measurement port and with terminals “HV Supply” and “GND” (of Figure 6) short circuited.

a0c0