2.3.2.

Artificial network

Power mains shall be applied to the vehicle through 50 µH/50 W artificial networks (AMN(s)) (see appendix 8 clause 4).
The AMN(s) shall be mounted directly on the ground plane (ALSE) or floor (OTS). The case of the AMN(s) shall be bonded to the ground plane (ALSE) or connected to the protective earth (OTS, e.g. an earth rod).
The measuring port of each AMN shall be terminated with a
50 W load.

a0c0