2.4.2.

Artificial network

AC power mains shall be applied to the vehicle through 50 µH/50 Ω AMN(s) (see Appendix 8, clause 4).
DC power mains shall be applied to the vehicle through 5 µH/50 Ω High Voltage Artificial Networks (DC-charging-AN(s)) (see Appendix 8, clause 3).
The AMN(s) / DC-charging-AN(s) shall be mounted directly on the ground plane (ALSE) or floor (OTS). The cases of the AMN(s) / DC-charging-AN(s) shall be bonded to the ground plane (ALSE) or connected to the protective earth (OTS, e.g. an earth rod).
The measuring port of each AMN / DC-charging-AN shall be terminated with a 50 Ω load.

a0c0