Measurement of the reflectance of non-flat (convex) mirrors requires the use of instruments which incorporate an integrating sphere in the receiver unit (see Figure 2). If the instrument-indicating meter indicates ne divisions with a standard mirror of E per cent reflectance, then, with a mirror of unknown reflectance, nx divisions will correspond to a reflectance of X per cent, in accordance with the formula: a0c0